Connection voltage 230V with mains cable and Euro plug.Output side with cable and plug-in distributor for up to 6 LED luminaires.Length 115, W 45, H 16mm
The luminaire accessory of the VIP90 family allows fluorescent lamps to be dimmed from 0 to 100% in conjunction with a suitable dimmer. At each period of the AC voltage, the VIP90 generates a strong pulse that safely ignites the fluorescent lamp. The ignition is therefore at 100Hz. A 4-wire cable is required to operate the luminaire. Only Leading-edge dimmers with at least 500W load capacity per channel are suitable.The advantages of VIP90 - Control from 0 to 100% (and vice versa) flicker-free - Always flawless ignition of the tubes, even when dimmed - No special lamps (lower costs) - No special ballasts - No additional ground load required (no energy loss) - Control ratio 1 to 10,000 ( depending on lamp type ).Operating voltage 220 - 230V, 50Hz - 60Hz Ambient temperature max. 60°C Different versions for PLC or LL available. e.g. VIP90 /3 = for fluorescent tubes TC-D 18W, TC-T 18W, PL-C 18W 4P, PL-T 18W 4P. The housing dimensions are constructed to fit into different fixture designs. Models are available for compact fixtures or bar fixtures.VIP90/3, tall shape Dimensions: L 220 mm, w 42 mm, h 28 mm.
Ideal for train, coach, ship, yacht, bus or boat etc.Controllable via an electronic potentiometer or a light control. If several luminaires are to be dimmed together via a single potentiometer, simply connect the control inputs of the ECGs in parallel. An additional power supply is not required. With preheating for flicker-free start Operating voltage 20V - 30V DC (nominal 24V)Ambient temperature -15°C ... + 50°CMax. Housing temperature Tc 80°C Energy class: B Mark of conformity: CE, FDimensions: L 290mm, W 50mm, H 40mm
Material: Flame retardant polycarbonate Insulation resistance: > 3 MOhm With fuse: 1A This starter bridge is suitable for use with the LED tubes we sell. Only luminaires with CCG or CCG may be used, ECG luminaires are not suitable. Instructions: Switch off the power supply to the luminaire, remove old tube and old starter, Insert starter bridge and new LED tube and turn until it clicks into place. Switch on the luminaire again.Delivery only in packaging of 25 pieces. The bridges are included free of charge with the purchase of our LED tubes.
Energy-saving electronic ballast for operating a fluorescent tube directly on the electrical system.With soft-start - flicker-free, gentle lamp start within two seconds.All our inverters are CE marked andCorrespondence electrically and mechanically with the Trenitalia legislation (S.T. 370430) for lighting on rail vehicles.These ballasts are CE marked and comply with European standards compliance (EN50311 latest revision).Not suitable for T5 lamps.Power stabilization - uniform light even with fluctuating battery voltage.Protected against input reverse polarityProtection against overvoltagesElectronic fuse with idle or defective lamp.Operating voltage: 26.5V DC DC voltage (18.5V - 35V).Operating current 0.77AInternal working frequency 38 KHzAmbient temperature -25 ° ... + 50 ° CMax. Housing temperature Tc 80 ° CLifetime:> 100,000 hours / 80 ° C /> 90%Energy class A3Housing made of aluminumProtection class: IP20Dimensions: L 235mm, W 36mm, H 30mmMinimum order quantity: 10 pcs.
Safe lamp start even at low ambient temperatures.Standard starter for single tube circuit. With interference suppression capacitor. To ensure safe lamp ignition, the starter should also be replaced each time the lamp is changed.
Ballast for DC or battery operation of sodium, MH metal halide or ceramic lamps 35W.Operating voltage 24V DC (short time 20V ... 30V DC)Current consumption: 1.72 amp (24V)Ambient temperature: -40°C ... +65°C.Ignition voltage 4.5 kVMetal housing openDimensions: l 110mm, w 110mm, h 50mmProtection degree - only for use in casings or lighting fixtures
Magnetic ballast for e.g. recessed ceiling luminaires.For HQI, HIT, CDM or sodium vapour lamps with 35W rated wattage.Incl. igniter.Access via 3-core cable with open ends,Lamp outlet via 3 individual cables.Fine-wire fuseTemperature cut-off,Operating voltage 220 - 240V 50HzProtection class: IP40 fully insulated - for indoor use onlyMark of conformity: F, CE, ENECDimensions: 143 x 122 x 62mm
To operate sodium, MH metal halide or ceramic lamps 50W in car, truck, boat or solar light.Small and rigid design.The unit must be mount on a heat-sink or on a metal housing, to reduce the operating temperature.Operating voltage 12V DC ... 24V DC (short time 10V ... 30V DC)Current consumption: 5 amp (12V), 2.46 amp (24V)Ambient temperature: -40°C ... +65°C.Ignition voltage 4.5 kVMetal housing hermetically closedDimensions: l 110mm, w 72mm, h 34mmProtection degree IP 66
Choke and compensation capacitor in waterproof housing.Optimised for Osram or Radium lamps.Connected voltage 230V/ 50HzOptionally available:Lamp current 8.2A (for metal halide lamp) or 9.5 - 10.3A (for sodium vapour lamp)Max. permissible length of connecting cable to the spotlight: 20mPlease order igniter separately.Sturdy protective housing splash-proof, greyProtection class IP 65Dimensions: 480 x 130 x 140 mm
Choke and compensation capacitor in waterproof housing.Optimised for Osram or Radium lamps.Supply voltage 400V/ 50HzLamp current: 8,8A or 10,3AMax. permissible length of connecting cable to headlamp: 50m.Please order igniter separately.Sturdy protective housing splash-proof, greyProtection class IP 65Dimensions: 480 x 130 x 140 mm
E.g. for recessed ceiling luminairesOperating voltage 220 - 240V 50HzFor indoor use only, IP40For HIT / CDM lamp 150W.incl. igniter.Dim.: L 250mm x W 70mm x H 75mm
Magnetic ballast for e.g. recessed ceiling luminaires.For HQI, HIT, CDM or sodium vapour lamps with 150W rated power.Incl. igniter.Access via 3-core cable with open ends,Lamp outlet via 3 individual cables.Fine-wire fuseTemperature cut-off,Operating voltage 220 - 240V 50HzProtection class: IP40 fully insulated - for indoor use onlyMark of conformity: F, CE, ENECDimensions: 143 x 122 x 62mm
Closed aluminium profile housing.For operating metal halide lamps HQI, HID, HCI, CDM, as well as high-pressure sodium lamps 150W.Operating voltage 24V DCOperating current: 6.45AAmbient temperature: -30°C ... +65°CIgnition voltage 4.5 kVLow-flicker light. Energy-saving and negligible reactive current.With overload protection and automatic switch-off in case of lamp failure.Protection class IP54Dimensions: L 203mm, W 102.5mm, H 65mm
There is no further ballast required.For T8 lamps: 58W or T5 54W or TC-L 55W (50W)High frequency control.Constant light flux, even at changing line voltage.No electrode flickering, no stroboscopic effects.Lamp warmstart possible at any dimming value.Automatic detection of the lamp type.Control input 1 ... 10V current sink (0.25 mA)Dimming range 1% ... 100%.If the complete cut-off of the lamp is desired, an additional relay must be installed.Operating voltage 180V ... 264V AC or DCEnergy class A1Power factor 0.97Dimensions: L 360mm, w 30 mm, h 29 mm
For T8 / T26 /T38 fluorescent lampsEnergy class: BEnergy savings of up to 25% compared to conventional ballasts.HF operation prolongs lamp life.Operating voltage 220V - 240V 50Hz - 60Hz.Dimensions: L 360mm, W 30 mm, H 29 mm
For T8 / T26 /T38 fluorescent lampsEnergy class A2Energy savings of up to 25% compared to conventional ballasts.HF operation prolongs lamp life.Operating voltage 230V.Dimensions: L 360mm, W 30 mm, H 29 mm
For operating sodium vapour, HQI or ceramic lamps 50W.Small, potted, waterproof,To reduce the housing temperature, mounting on a heat sink or on a metal housing is required.Operating voltage: 198 - 264V 50Hz - 60HzOperating current: 0.36 AAmbient temperature: -40°C ... +65°C. Ignition voltage: 4.5 kVMetal housing encapsulatedDimensions: L 110mm, W 72mm, H 34mmProtection class IP66
Magnetic ballast for e.g. recessed ceiling luminaires.For HQI, HIT, CDM or sodium vapour lamps with 70W - 75W rated wattage.Incl. igniter.Access via 3-core cable with open ends,Lamp outlet cable with Wieland 3-pole connector.Cable compartment can be opened, underneath are 2 three terminal strips with 2 strain reliefs.Temperature cut-off,Operating voltage 220 - 240V 50HzProtection class: IP20 Fully insulated - For indoor use onlyMark of conformity: F, CEDimensions: L 200 / 224mm x W 85mm x H 74mm
€44.03*
* Preise inkl. MwSt. zzgl. Versandkosten
This website uses cookies to ensure the best experience possible. More information...